POST Error Messages continued
Error Code Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
163-Time & Date Not
Set
2S Invalid time or date in
configuration memory.
Run the System
Configuration Utility
and correct.
164-Memory Size
Error
2S Configuration memory
incorrect
Run the System
Configuration Utility
and correct.
170-Expansion
Device Not
Responding
None EISA or PCI expansion
board failure
Check board for secure
installation. Replace
the failed board if
necessary.
172- Configuration
Nonvolatile Memory
Invalid
None Nonvolatile configuration
corrupt or jumper
installed.
Run the System
Configuration Utility
and correct.
172-1 Configuration
Nonvolatile Memory
Invalid
None Nonvolatile configuration
corrupt.
Run the System
Configuration Utility
and correct.
173-Slot ID Mismatch None Board replaced,
configuration not updated.
Run the System
Configuration Utility
and correct.
174-Configuration
/Slot Mismatch
Device Not Found
None EISA or PCI board not
found.
Run the System
Configuration Utility
and correct.
175-Configuration
/Slot Mismatch
Device Found
None EISA or PCI board added,
configuration not updated.
Run the System
Configuration Utility
and correct.
176-Slot with Not
Readable ID Yields
Valid ID
None EISA or PCI board in slot
that should contain an ISA
board.
Run the System
Configuration Utility
and correct.
continued