POST Error Messages continued
Error Code Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
177-Configuration
Not Complete
None Incomplete System
Configuration.
Run the System
Configuration Utility
and correct.
178-Processor
Configuration Invalid
None Processor type or step
does not match
configuration memory.
Run the System
Configuration Utility
and correct.
179-System Revision
Mismatch
None A board was installed that
has a different revision
date.
Run the System
Configuration Utility
and correct.
201-Memory Error None RAM failure Run Diagnostics.
203-Memory Address
Error
None RAM failure Run Diagnostics.
205-Cache Memory
Error
None Cache memory error Replace the processor
board in the slot
indicated.
205-Option Cache
Memory Error
None Option cache memory
error
Replace the option
cache board.
206-Cache Controller
Error
None Cache controller failure Run Diagnostics.
207-Invalid Memory
Configuration - Check
DIMM [SIMM]
Installation
None Memory module installed
incorrectly
Verify placement of
memory modules.
continued

Table of Contents