8-9
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
POST Error Messages continued
Error Code Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1702-SCSI cable error
detected
System halted.
None Incorrect cabling 1.For Integrated SCSI
Controllers, ensure
that the internal
connector has SCSI
termination
attached.
2.For option card SCSI
controllers, ensure
that only one of the
two internal
connectors has
termination
attached.
1703-SCSI cable error
detected. Internal
SCSI cable not
attached to system
board connector.
System halted.
None Incorrect cabling Ensure that the
integrated SCSI
controller has SCSI
termination attached.
1704-Unsupported
Virtual Mode Disk
Operation. DOS Driver
Required. System
Halted.
None System attempted to
perform a virtual mode
disk operation without
virtual mode memory
services.
Use fixed-disk device
driver that supports
virtual mode memory
services.
1705-Locked SCSI
Bus Detected. System
Halted.
None SCSI bus failure Run Diagnostics.
Contact your service
provider.
1730-Fixed Disk 0
does not support
DMA Mode
None Fixed disk drive error Run the System
Configuration Utility
and correct.
continued

Table of Contents