8-14 Diagnostics Tools
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
POST Error Messages continued
Error Code Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1777-Drive Array -
External Drive
Subsystem Error
None Cooling fan failure,
internal temperature alert
or open side panel.
Inspect for cooling fan
failure or side panel
open.
1778-Drive Array
resuming Automatic
Data Recovery
process
None This message appears
whenever a controller
reset or power cycle
occurs while Automatic
Data Recovery is in
progress.
No action necessary.
1779-Drive Array
Controller detects
replacement drives
None Intermittent drive failure
and/or possible loss of
data.
If this message
appears and drive X
has not been replaced,
this indicates an
intermittent drive
failure. This message
also appears once
immediately following
drive replacement
when data must be
restored from backup.
1780-Disk 0 Failure None Hard drive/format error Run Diagnostics.
Replace failed
assembly or contact
your service provider.
1781-Disk 1 Failure None Hard drive/format error Run Diagnostics.
Replace failed
assembly or contact
your service provider.
1782-Disk Controller
Failure,
Secondary Disk
Controller Failure
None Hard disk drive circuitry
error
Run Diagnostics.
Replace failed
assembly or contact
your service provider.
continued

Table of Contents

Related product manuals