8-43
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
DAAD Diagnostic Messages continued
Message Description Recommended Action
Drive (bay) X needs
replacing (DAAD Error
102)
The 210-megabyte hard
drive has firmware version
2.30 or 2.31.
Replace the drive.
Drive Monitoring features
are unobtainable
DAAD unable to get
monitor and performance
data due to fatal command
problem such as drive
time-out, or unable to get
data due to these features
not supported on the
controller.
Check for other errors (time-outs, etc.). If no
other errors occur, upgrade the firmware to a
version that supports monitor and performance,
if desired.
Drive Monitoring is NOT
enabled for drive bay X
The monitor and
performance features have
not been enabled.
Run the System Configuration Utility to initialize
the monitor and performance features.
Drive time-out occurred
on physical drive bay X
DAAD issued a command
to a physical drive and the
command was never
acknowledged.
The drive or cable may be bad. Check the other
error messages on the Diagnostics screen to
determine resolution.
Drive (bay) X firmware
needs upgrading
Firmware on this physical
drive is below the latest
recommended version.
Run the Options ROMPaq Utility to upgrade the
drive firmware to the latest revision.
continued