DAAD Diagnostic Messages continued
Message Description Recommended Action
Drive (bay) X has invalid
M&P stamp
Physical drive has invalid
monitor and performance
data.
Run the System Configuration Utility to properly
initialize this drive.
Drive X indicates position
Y
Message indicates which
physical drive appears to
be scrambled or in a drive
bay other than the one for
which it was originally
configured for.
Examine the graphical drive representation on
DAAD to determine proper drive locations.
Remove drive X and place it in drive position Y.
Rearrange the drives according to the DAAD
instructions.
Drive (bay) X RIS copy
mismatch
The copies of the RIS on
this drive do not match.
This drive may need to be replaced. Check for
other errors.
Drive (bay) X upload code
not readable
An error occurred while
DAAD was trying to read
the upload code
information from this drive.
If there were multiple errors, this drive may
need to be replaced.
Duplicate write memory
error
Data could not be written
to the array accelerator
board in duplicate due to
the detection of parity
errors. This is not a data
loss situation.
Replace the array accelerator board.
Error occurred reading
RIS copy from drive (bay)
X
An error occurred while
DAAD was trying to read
the RIS from this drive.
If there were multiple errors, this drive may
need to be replaced.
continued