Compaq ProLiant 800 Server Reference Guide
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
DAAD Diagnostic Messages continued
Message Description Recommended Action
Logical Drive X status =
FAILED
This status could be
issued for several reasons.
If this logical drive is
configured for No Fault
Tolerance and one or more
drives fail, this status will
occur. If mirroring is
enabled, and any two
mirrored drives fail, this
status will occur. If Data
Guarding is enabled, and
two or more drives fail in
this unit, this status will
occur. This status may
also occur if another
configured logical drive is
in the WRONG DRIVE
REPLACED or LOOSE
CABLE DETECTED state.
Check for drive failures, wrong drive replaced,
or loose cable messages. If there was a drive
failure, replace the failed drive(s) and then
restore the data for this logical drive from the
tape backup. Otherwise, follow the wrong drive
replaced or loose cable detected procedures.
Logical Drive X status =
INTERIM RECOVERY
A physical drive in this
logical drive has failed.
The logical drive is
operating in interim
recovery mode and is
vulnerable.
Replace the failed drive as soon as possible.
Logical Drive X status =
LOOSE CABLE DETECTED
A physical drive has a
cabling problem.
Turn the system off and attempt to reattach the
cable onto the drive. If this does not work,
replace the cable.
continued