8-48 Diagnostics Tools
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
DAAD Diagnostic Messages continued
Message Description Recommended Action
Logical Drive X status =
NEEDS RECOVER
A physical drive in this
logical drive has failed and
has now been replaced.
This drive needs to be
rebuilt from the mirror
drive or the parity data.
When booting up the system, select the "F1 -
rebuild drive" option to rebuild the replaced
drive.
Logical Drive X status =
OVERHEATED
The temperature of the
Intelligent Array Expansion
System drives is beyond
safe operating levels and it
has shut down to avoid
damage.
Check the fans and the operating environment.
Logical Drive X status =
OVERHEATING
The temperature of the
Intelligent Array Expansion
System drives is beyond
safe operating levels.
Check the fans and the operating environment.
Logical Drive X status =
RECOVERING
A physical drive in this
logical drive has failed and
has now been replaced.
The replaced drive is
rebuilding from the mirror
drive or the parity data.
Nothing needs to be done. Normal operations
can occur.
Logical Drive X status =
WRONG DRIVE
REPLACED
A physical drive in this
logical drive has failed.
The incorrect drive was
replaced.
Replace the drive that was incorrectly replaced.
Then, replace the original drive that failed with
a new drive. Do not run the System
Configuration Utility to reconfigure - you will
lose data on the drive.
continued