2-7
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Server Management Comments:
File Name: D-ch2.doc Last Saved On: 4/23/97 11:14 AM
Critical Error Log Messages continued
Message Description
Automatic Server Recovery
Base Memory Parity Error
The system detected a data error in base memory
following a reset due to the Automatic Server
Recovery-2 (ASR-2) timer expiration.
Automatic Server Recovery
Extended Memory Parity Error
The system detected a data error in extended
memory following a reset due to the ASR-2 timer
expiration.
Automatic Server Recovery
Memory Parity Error
The system ROM was unable to allocate enough
memory to create a stack. Then it was unable to put
a message on the screen or continue booting the
server.
Automatic Server Recovery Reset
Limit Reached
The maximum number of system resets due to ASR-2
timer expiration has been reached, resulting in the
loading of Compaq Utilities.
Battery Failing Low system battery warning. Replace battery within 7
days to prevent loss of nonvolatile configuration
memory. Failure of the battery supporting the
system’s nonvolatile RAM is imminent.
Caution: Temperature Exceeded The operating system has detected that the
temperature of the system has exceeded the caution
level. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the
operating system.
Diagnostic Error An error was detected by the Diagnostics Utility. See
the specific error code in this chapter for a detailed
explanation.
Error Detected On Boot Up The server detected an error during the Power-On
Self-Test (POST).
continued