Cleaning and Maintenance
User manual 162
Error code Description of fault Required response
E25.0
Condenser sensor (B3) open circuit Contact customer service
E25.1
Condenser sensor (B3) has a ground fault Contact customer service
E26.0
Thermal cutout (B8) open circuit Contact customer service
E26.1
Thermal cutout (B8) has a ground fault Contact customer service
E27.0 Thermal cutout (B8) is reading too high a
temperature
Contact customer service
E29.1
E29.2
E29.3
E29.4
Core temperature sensor (CTS) has a ground
fault
Contact customer service
E33.0
Steam generator malfunction
Get customer service to test and reset the
thermal cutout N7
E34.0
Steam-generator pump fault:
pump does not turn on
1. Unplug the appliance for approx. 10
seconds and restart
2. Disable steam generator rinsing and
contact customer service
E83.0
Inadmissible cooking function
1. Re-enter the cooking program
2. Contact customer service
E89.1
Invalid data in the identification module (IDM)
1. Unplug the appliance for approx. 10
seconds and restart
2. Contact customer service
E96.0
Communications error
1. Unplug the appliance for approx. 10
seconds and restart
2. Contact customer service
E99.x
General initialization error
Unplug the appliance for approx. 10 se-
conds and restart

Table of Contents