Layout and function
User manual 31
Appliance technical standards
The following table shows the technical standards for the appliance:
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Table-top appliances Floor-standing appliances
Degree of protection IPX5
Approval mark*
TÜV/GS, DIN GOST TÜV, SVGW, WRAS, UL, NSF
Noise emission
measured [dBA] < 70
*The appliance only displays those approval marks relevant to the country of use.
Water supply
The following table shows the values for the water supply:
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Table-top applian-
ces
Floor-standing
appliances
Water supply (cold only)
Shut-off device
with non-return valve (type EA) and dirt filter
Water supply
without ConvoClean
system
G 3/4'', permanent connection optional with min. DN 10 supply pipe
with ConvoClean system
G 3/4'', permanent connection optional with min. DN 10 supply pipe
Flow pressure
without ConvoClean
system
[kPa]
200 - 600 (2 - 6 bar)
with ConvoClean system
[kPa]
300 - 600 (3 - 6 bar)
Water drain*
Type
DN
50 50 50 50 50 50 50
* Permanent connection (recommended) or funnel waste trap