Layout and function
User manual 34
Electrical installed load ratings
The following table shows the electrical installed load ratings:
OGB
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Table-top applian-
ces
Floor-standing
appliances
3N~ 400V 50/60Hz (3/N/PE)
Rated power consumption [kW] 1,2 1,2 1,2 1,5 1,5 2,2 2,2
Rated current [A] 2,9 2,9 2,9 3,6 3,6 5,1 5,4
Fuse [A] 16 16 16 16 16 16 16
recommended conductor
cross-section*
[mm
2
] 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5
3~ 230V 50/60Hz (3/PE)
Rated power consumption [kW] 1,4 1,4 1,4 1,8 1,8 2,6 2,7
Rated current [A] 4,9 4,9 4,9 6,2 6,2 9,1 9,4
Fuse [A] 16 16 16 16 16 16 16
recommended conductor
cross-section*
[mm
2
] 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5
*recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.
Gas supply
The following table shows the values for the gas supply:
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Table-top applian-
ces
Floor-standing
appliances
Fuels
Natural gas, liquid gas
Flue gas connection
Air conditioning system with safety shutdown
Appliance technical standards
The following table shows the technical standards for the appliance:
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Table-top appliances Floor-standing appliances
Degree of protection IPX5
Approval mark*
Gastec QA, DIN GOST TÜV, SVGW, WRAS, UL, NSF, JIA, AGA
Noise emission
measured [dBA] < 70
*The appliance only displays those approval marks relevant to the country of use.