6 Errors and malfunctions
Operator manual: Postmix tower
Ribbon
50
Cornelius Deutschland GmbH
Document no. TD0000000
Version: 19/10/2017, Index 3
6 Errors and malfunctions
6.1 Troubleshooting table
Continued overleaf
Notice!
All installation, maintenance and repair work at the unit is to be carried out
by an expert only.
Fault Probable cause Remedy
Unable to dispense
No mains/power supply con-
nected
Check the plug on the E-Box and
mains plug and plug in if neces-
sary (see chapter 4.5, page 37)
Automatic circuit breaker on the
E-Box has tripped
Switch on the automatic circuit
breaker on the E-Box (see
chapter 4.5, page 37)
Automatic circuit breaker on the
E-Box is defective
Please contact your service part-
ner
Tower is not switched on
Turn the key switch to position "I”
(see chapter 4.5, page 37)
Touchscreen is defective
Please contact your service part-
ner
Fault or error on the undercounter
cooler
See the document Undercounter
cooler operator manual”
Beverage is too
warm and the com-
pressor is not run-
ning
Fault or error on the undercounter
cooler
See the document Undercounter
cooler operator manual”
Beverage is too
warm and the com-
pressor is running
Fault or error on the undercounter
cooler
See the document Undercounter
cooler operator manual”