6 Errors and malfunctions
Operator manual: Postmix tower
Ribbon
51
Cornelius Deutschland GmbH
Document no. TD0000000
Version: 19/10/2017, Index 3
Continued overleaf
Fault Probable cause Remedy
Beverage foams for
all products
All beverages are too warm Check storage temperature
CO
2
feed pressure for the soda
circuit is too high on the relevant
pressure-reducing valve
Adjust the CO
2
feed pressure to
the required value (see documen-
tation on the CO
2
system)
CO
2
feed pressure for the syrup
circuit is set incorrectly on the rel-
evant pressure-reducing valve
Adjust the CO
2
feed pressure to
the required value (see documen-
tation on the CO
2
system)
Fault or error on the undercounter
cooler
See the document “Undercounter
cooler operator manual”
Contaminated tubes
Please contact your service part-
ner
Only soda is being
dispensed
Syrup container is empty
Connect a new syrup container
(see the document “Undercoun-
ter cooler operator manual”)
Connections on the syrup con-
tainer are not properly connected
Connect the connections on the
syrup container properly (see doc-
umentation on the syrup con-
tainer)
CO
2
feed pressure for the syrup
circuit is set incorrectly on the rel-
evant pressure-reducing valve
Adjust the CO
2
feed pressure to
the required value (see documen-
tation on the CO
2
system)
Syrup tube is not connected to the
syrup container
Connect the syrup tube (see the
document “Undercounter cooler
operator manual”)
Syrup tube is contaminated
Please contact your service part-
ner
Syrup tube defective
Please contact your service part-
ner
Incorrectly set valve on the tower
Please contact your service part-
ner
Defective valve on the tower
Please contact your service part-
ner