6 Errors and malfunctions
Operator manual: Postmix tower
Ribbon
52
Cornelius Deutschland GmbH
Document no. TD0000000
Version: 19/10/2017, Index 3
Fault Probable cause Remedy
Only syrup is being
dispensed
Shut-off valve or pressure-reduc-
ing valve for the fresh water sup-
ply is closed
Open the shut-off valve and pres-
sure-reducing valve for the fresh
water supply (see documentation
on the drinking water system)
Fault or error on the undercounter
cooler
See the document Undercounter
cooler operator manual”
Soda/syrup ratio is
incorrect
Too little/too much soda
Check the flow setting for soda
(see chapter 4.3.2.2, page 27)
Too little/too much syrup
Check the flow setting for the rele-
vant product (see chapter 4.3.2.2,
page 27)
CO
2
feed pressure for the syrup
circuit is set incorrectly on the rel-
evant pressure-reducing valve
Adjust the CO
2
feed pressure to
the required value (see documen-
tation on the CO
2
system)
Insufficient amount
of CO2 in the bev-
erage
CO
2
pressure for soda is set
incorrectly on the relevant pres-
sure-reducing valve
Correctly adjust the CO
2
pres-
sure for soda on the relevant
pressure-reducing valve (see doc-
umentation on the CO
2
system)
Fault or error on the undercounter
cooler
See the document Undercounter
cooler operator manual”
CO
2
supply is contaminated
Please contact your service part-
ner
Notice!
Crushed ice in the cup may also cause dispensing problems.
When the finished beverage comes into contact with sharp-edged ice,
CO2 is released from the dispensed beverage.