<3> SNTP: Activate NTP client and set up to two NTP server IP addresses.
<1> Active [Disable]
<2> Server 1 [0.0.0.0]
<3> Server 2 [0.0.0.0]
<4> Time Zone: Set the hours from UTC up to 12 or -12 and set minutes if TZ does not fall on the hour (such as in India).
{ System > Time Zone }
<1> Hours [0]
<2> Minutes [0]
<5> Log: View the log record of the device
{ System > Log }
ID Time & Message
---------- --------------
1 2022-02-11T15:08:08+08:00
SYS-BOOTING: Switch just made a cold boot.
2 2022-02-11T15:08:08+08:00
LINK-UP: Local LAN Port, changed state to up
3 2022-02-11T15:08:08+08:00
LINK-UP: Local FIBER Port, changed state to up
4 2022-02-11T15:08:11+08:00
REMOTE: FMC-2000MS UP
<6> Work in [Switch] Mode: The normal mode of operation for this device is "Switch" mode. The store and forward mechanism between
the LAN and FIBER ports allows for different speeds and duplexes between the two, for example 10Base or 100Base on the LAN while the
FIBER speed is 1000Base. In "Converter" mode, the devices work in low latency, no store and forward, and LAN and FIBER must match speed
and duplex. In addition, in "Converter" mode, there will be no IP access (telnet, SNMP, Web disabled) and with IEEE802.3ah OAM disabled,
there is no in-band management of any remote device.
----------------------------------------------------------
<0> Converter <1> Switch <ESC> Exit