3.3 Troubleshooting
3.3.1 Factory Default.
Apply power to FMC-2000MS and allow 15-20 seconds to fully boot. Using a pencil or ball-point pen, press the 'DEFAULT' recessed push-
button switch (located on the face plate) and hold for 6 seconds or more then release. DO NOT POWER OFF; Allow the unit to again fully reboot
(about 25 seconds). The factory default TCP/IP settings are:
IP=10.1.1.1
netmask=255.255.255.0
GW=10.1.1.254
The password is reset to [blank].
Additionally, any VLAN, 1Q or Q in Q will be disabled. All ports will be enabled, UTP ports set for auto-negotiation and no bandwidth limiting
on any port.
3.3.2 LED Observations
3.3.2.1 Power On
At initial power on, PWR LED will be lit.
Error conditions :
If all LEDs immediately light and never turn off, or if no LED ever lights, then the card is possibly defective. Be sure to double check power
source and try either another FMC-2000MS in the same chassis or try the card in a different chassis or with a different power adapter.