DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch 
183 
 
Port 
Use the drop-down menu to choose the port that will display statistics. 
Time Interval  
Select the desired setting between 1s and 60s, where "s" stands for seconds. The default 
value is one second. 
Record Number  
Select number of times the Switch will be polled between 20 and 200. The default value is 
200. 
64 
The total number of packets (including bad packets) received that were 64 octets in length 
(excluding framing bits but including FCS octets). 
65-127 
The total number of packets (including bad packets) received that were between 65 and 
127 octets in length inclusive (excluding framing bits but including FCS octets). 
128-255 
The total number of packets (including bad packets) received that were between 128 and 
255 octets in length inclusive (excluding framing bits but including FCS octets). 
256-511 
The total number of packets (including bad packets) received that were between 256 and 
511 octets in length inclusive (excluding framing bits but including FCS octets). 
512-1023 
The total number of packets (including bad packets) received that were between 512 and 
1023 octets in length inclusive (excluding framing bits but including FCS octets). 
1024-1518 
The total number of packets (including bad packets) received that were between 1024 and 
1518 octets in length inclusive (excluding framing bits but including FCS octets). 
Show/Hide 
Check whether or not to display 64, 65-127, 128-255, 256-511, 512-1023, and 1024-1518 
packets received. 
Clear 
Clicking this button clears all statistics counters on this window. 
View Table  Clicking this button instructs the Switch to display a table rather than a line graph. 
View Graphic  Clicking this button instructs the Switch to display a line graph rather than a table.