200416 4-3
Inspection and adjustment
CE ENGINE FUEL SYSTEM
ΧΦ65/75/85 series
4
2
4.2 VENTING THE FUEL SYSTEM
When venting the fuel system, a
quantity of fuel will escape. Collect
the fuel and avoid the risk of fire.
Stop pumping as soon as a
resistance is felt. If you continue
pumping, the fuel system may
become internally damaged.
Note:
When the primer pump is used, the fuel system
will be automatically vented. Air will be fed back
to the tank through the return line.
Racor fuel prefilter/water separator
1. Open the vent plug (2) a couple of turns.
2. Pump the primer pump (1) until fuel comes
out of the vent plug (2).
3. Close the vent plug (2).
4. Use the primer pump until a clearly higher
resistance is felt.
}
}
1
2
3
4
5
7
6
8
i400356
https://www.truck-manuals.net/