9 | LAN adapter
Installer reference guide
103
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
Smart Grid application
Item Requirement
LAN adapter software It is recommended to ALWAYS keep the LAN adapter
software up-to-date.
Unit control method On the user interface, make sure to set [2.9]=2
(Control = Room thermostat)
Domestic hot water
settings
To allow for energy buffering in the domestic hot
water tank, on the user interface, make sure to set
[9.2.1]=4 (Domestic hot water = Integrated).
Power consumption
control settings
On the user interface, make sure to set:
▪ [9.9.1]=1 (Power consumption control =
Continuous)
▪ [9.9.2]=1 (Type = kW)
INFORMATION
For instructions on how to perform a software update, see "9.4.4 Updating
software"[4113].
9.1.3 On-site installation requirements
What you need on site to install the LAN adapter depends on the system layout.
BRP069A61 BRP069A62
Always
PC/laptop with Ethernet connector
Router (DHCP enabled)
Smartphone with the Daikin Residential Controller app
Depending on the system layout
IF connection to an
electricity meter (X2A)
Electricity meter —
2‑wire cable —
IF connection to a solar
inverter/energy
management system
(X1A)
2‑wire cable —
Circuit breaker
(100mA~6A, typeB)
—