8 | Electrical installation
Installer reference guide
78
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
8 Electrical installation
8.1 About connecting the electrical wiring
Before connecting the electrical wiring
Make sure the brine and water piping are connected.
Typical workflow
Connecting the electrical wiring typically consists of the following stages:
See "8.2 Overview of electrical connections for external and internal
actuators"[480].
8.1.1 Precautions when connecting the electrical wiring
DANGER: RISK OF ELECTROCUTION
INFORMATION
Also read the precautions and requirements in the "General safety precautions"
chapter.
WARNING
All wiring MUST be performed by an authorised electrician and MUST comply
with the applicable legislation.
Make electrical connections to the fixed wiring.
All components procured on-site and all electrical construction MUST comply
with the applicable legislation.
WARNING
If the power supply has a missing or wrong N-phase, equipment might break
down.
Establish proper earthing. Do NOT earth the unit to a utility pipe, surge absorber,
or telephone earth. Incomplete earthing may cause electrical shock.
Install the required fuses or circuit breakers.
Secure the electrical wiring with cable ties so that the cables do NOT come in
contact with sharp edges or piping, particularly on the high-pressure side.
Do NOT use taped wires, stranded conductor wires, extension cords, or
connections from a star system. They can cause overheating, electrical shock or
fire.
Do NOT install a phase advancing capacitor, because this unit is equipped with an
inverter. A phase advancing capacitor will reduce performance and may cause
accidents.
WARNING
ALWAYS use multicore cable for power supply cables.