5 | Application guidelines
Installer reference guide
45
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
#5: Single cable power supply
(=combined power supply)
+
Preferential kWh rate power supply
with separate normal kWh rate power
supply
NOT ALLOWED
#6: Dual cable power supply (=split
power supply)
+
Preferential kWh rate power supply
with separate normal kWh rate power
supply
C1C5 C3
C4
a1a3
X5M/5+6
X5M
X2M
S1S
b1
c d e
X5M/3+4
b2
5
8
0
1
5
0
0
0
5
8
0
1
5
0
0
0
450896.005
C2
F3BF1B
F2B
Legend:
a Electrical cabinet:
a1 Normal kWh rate power supply (1N~ or 3N~ depending on
the backup heater)
a2 Preferential kWh rate power supply (1N~ or 3N~ depending
on the backup heater)
a3 Preferential kWh rate power supply (1N~)
b b1 Power meter 1 (1N~ or 3N~ depending on the backup
heater)
b2 Power meter 2 (1N~)
For details about connecting the power meters to the unit, see
"8.2.4To connect the electricity meters"[490].
c Compressor (1N~)
d Hydro (1N~)
e Backup heater (1N~ or 3N~)
C1~C5 For details about C1~C5, see "8.2.1To connect the main power
supply"[482].
F1B~F3B Overcurrent fuse
S1S Preferential kWh rate power supply contact
5.6 Setting up the power consumption control
You can use the following power consumption controls. For more information
about the corresponding settings, see "Power consumption control"[4190].