10 | Configuration
Installer reference guide
131
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
For the setting… Refer to…
Indoor unit type (read only) "10.5.9Installer settings"[4183]
Backup heater type (read only)
Domestic hot water [9.2.1]
Emergency [9.5.1]
Number of zones [4.4] "10.5.5Space heating/
cooling"[4164]
Backup heater
Voltage [9.3.2] "Backup heater"[4184]
Maximum capacity [9.3.9]
Main zone
Emitter type [2.7] "10.5.3Main zone"[4150]
Control [2.9]
Setpoint mode [2.4]
Heating WD curve [2.5] (if
applicable)
Cooling WD curve [2.6] (if
applicable)
Schedule [2.1]
WD curve type [2.E]
Additional zone (only if [4.4]=1)
Emitter type [3.7] "10.5.4Additional zone"[4159]
Control (read only) [3.9]
Setpoint mode [3.4]
Heating WD curve [3.5] (if
applicable)
Cooling WD curve [3.6] (if
applicable)
Schedule [3.1]
WD curve type [3.C]
Tank
Heat up mode [5.6] "10.5.6Tank"[4171]
Comfort setpoint [5.2]
Eco setpoint [5.3]
Reheat setpoint [5.4]
Hysteresis [5.9] and [5.A]
WD curve type [5.E]