Breadcrumb Field code Setting name Range, step
Default value
Date Value
Field settings table
Installer setting at variance with
default value
5.7.2 [2-00] R/W 0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunda
y
5.7.3 [2-02] R/W 0~23 hour, step: 1 hour
3
5.7.4 [2-03] R/O 60°C
60°C
5.7.5 [2-04] R/W 40~60 min, step: 5 min
40 min
Tank
5.8 [6-0E] R/W 40~60°C, step: 1°C
60°C
5.9 [6-00] R/W
2~20°C, step: 1°C
6°C
5.A [6-08] R/W
2~20°C, step: 1°C
10°C
5.B R/W
0: Fixed
1: Weather de
p
endent
└─ WD curve
5.C [0-0B] R/W 35~[6-0E]°C, step: 1°C
55°C
5.C [0-0C] R/W 45~[6-0E]°C, step: 1°C
60°C
5.C [0-0D] R/W 10~25°C, step: 1°C
15°C
5.C [0-0E] R/W -40~5°C, step: 1°C
-10°C
Tank
5.D [6-01] R/W 0~10°C, step: 1°C
2°C
User settings
└─ Quiet
7.4.1 R/W
0: OFF
1: Quiet
2: More quiet
3: Most quiet
4: Automatic
└─ Electricity price
7.5.1 R/W 0,00~990/kWh
1/kWh
7.5.2 R/W 0,00~990/kWh
1/kWh
7.5.3 R/W 0,00~990/kWh
1/kWh
User settings
7.6 R/W 0,00~990/kWh
0,00~290/MBtu
1,0/kWh
Installer settings
└─ Configuration wizard
└─ System
9.1.3.2 [E-03] R/O
4: 9W
9.1.3.3 [E-05]
[E-06]
[E-07]
R/W No DHW
Integrated
9.1.3.4 [4-06] R/W 0: Manual
1: Automatic (normal SH/ DHW ON)
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
9.1.3.5 [7-02] R/W
0: Single zone
1: Dual zone
└─ Backup heater
9.1.4.1 [5-0D] R/W 0: 230V, 1~
2: 400V, 3~
9.1.4.5 [4-07] R/W [5-0D]=2: 0~9 kW, step 1 kW
9 kW
[5-0D]2: 0~6 kW, step 1 kW
6 kW
└─ Main zone
9.1.5.1 [2-0C] R/W 0: Underfloor heating
1: Fancoil unit
2: Radiator
9.1.5.2 [C-07] R/W
0: LWT control
1: Ext RT control
2: RT control
9.1.5.3 R/W 0: Fixed
1: WD heating, fixed cooling
2: Weather de
p
endent
9.1.5.4 R/W
0: No
1: Yes
9.1.5.5 0: 2-points
1: Slo
p
e-Offset
9.1.6 [1-00] R/W -40~5°C, step: 1°C
-40°C
9.1.6 [1-01] R/W 10~25°C, step: 1°C
15°C
9.1.6 [1-02] R/W
[9-01]~[9-00], step: 1°C
[2-0C]=0
45°C
[2-0C]=1
55°C
[2-0C]=2
65°C
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
WD curve type
Control
Setpoint mode
Maximum BUH capacity
Schedule
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
BUH type
Domestic hot water
Emergency
Number of zones
Voltage
Emitter type
Margin
Activation
High
Medium
Low
Gas price
Hysteresis
Setpoint mode
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Operation day
Start time
Tank setpoint
Duration
Maximum
Hysteresis
4P569818-1A - 2019.10 (#) Setting is not applicable for this unit. (*1) *X*_(*2) *H*