Breadcrumb Field code Setting name Range, step
Default value
Date Value
Field settings table
Installer setting at variance with
default value
9.I [0-00] R/W [9-05]~min(45,[9-06])°C, step: 1°C
[2-0C]=0
22°C
[2-0C]=1
35°C
[2-0C]=2
25°C
9.I [0-01] R/W [9-05]~[9-06]°C, step: 1°C
[2-0C]=0
45°C
[2-0C]=1
55°C
[2-0C]=2
65°C
9.I [0-02] R/W 10~25°C, step: 1°C
15°C
9.I [0-03] R/W -40~5°C, step: 1°C
-40°C
9.I [0-04] R/W [9-07]~[9-08]°C, step: 1°C
8°C
9.I [0-05] R/W [9-07]~[9-08]°C, step: 1°C
12°C
9.I [0-06] R/W 25~43°C, step: 1°C
35°C
9.I [0-07] R/W 10~25°C, step: 1°C
20°C
9.I [0-0B] R/W 35~[6-0E]°C, step: 1°C
55°C
9.I [0-0C] R/W 45~[6-0E]°C, step: 1°C
60°C
9.I [0-0D] R/W 10~25°C, step: 1°C
15°C
9.I [0-0E] R/W -40~5°C, step: 1°C
-10°C
9.I [1-00] R/W -40~5°C, step: 1°C
-40°C
9.I [1-01] R/W 10~25°C, step: 1°C
15°C
9.I [1-02] R/W
[9-01]~[9-00], step: 1°C
[2-0C]=0
45°C
[2-0C]=1
55°C
[2-0C]=2
65°C
9.I [1-03] R/W [9-01]~min(45, [9-00])°C , step: 1°C
[2-0C]=0
22°C
[2-0C]=1
35°C
[2-0C]=2
25°C
9.I [1-04] R/W 0: Disabled
1: Enabled
9.I [1-05] R/W 0: Disabled
1: Enabled
9.I [1-06] R/W 10~25°C, step: 1°C
20°C
9.I [1-07] R/W
25~43°C, step: 1°C
35°C
9.I [1-08] R/W [9-03]~[9-02]°C, step: 1°C
22°C
9.I [1-09] R/W [9-03]~[9-02]°C, step: 1°C
18°C
9.I [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
9.I [1-0B] R/W 3~10°C, step: 1°C
10°C
9.I [1-0C] R/W 3~10°C, step: 1°C
10°C
9.I [1-0D] R/W 3~10°C, step: 1°C
5°C
9.I [1-0E] R/W 3~10°C, step: 1°C
5°C
9.I [2-00] R/W 0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunda
y
9.I [2-01] R/W 0: No
1: Yes
9.I [2-02] R/W 0~23 hour, step: 1 hour
3
9.I [2-03] R/O
60°C
9.I [2-04] R/W 40~60 min, step: 5 min
40 min
9.I [2-05] R/W 4~16°C, step: 1°C
8°C
9.I [2-06] R/W 0: Disabled
1: Enabled
9.I [2-09] R/W -5~5°C, step: 0,5°C
0°C
9.I [2-0A] R/W -5~5°C, step: 0,5°C
0°C
9.I [2-0B] R/W -5~5°C, step: 0,5°C
0°C
Adjust the offset on the measured room temperature
Adjust the offset on the measured room temperature
What is the required offset on the measured outdoor temp.?
Should the disinfection function be executed?
When should the disinfection function start?
What is the disinfection target temperature?
How long must the tank temperature be maintained?
Room antifrost temperature
Room frost protection
What is the averaging time for the outdoor temp?
What is the desired delta T in heating for the main zone?
What is the desired delta T in heating for the additional zone?
What is the desired delta T in cooling for the main zone?
What is the desired delta T in cooling for the additional zone?
When should the disinfection function be executed?
Weather dependent cooling of the main leaving water temperature zone.
Weather dependent cooling of the additional leaving water temperature zone
Low ambient temp. for LWT main zone cooling WD curve.
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
High ambient temp. for LWT add zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
(*1) *X*_(*2) *H* (#) Setting is not applicable for this unit. 4P569818-1A - 2019.10