uest
└─ Brine freezing temperature
9.M [A-04] R/W
0: 2°C
1: -2°C
2: -4°C
3: -6°C
4: -9°C
5: -12°C
6: -15°C
7: -18°C
What is the brine anti freeze temperature?
Close shut-off valve during thermo OFF?
Pump operation during flow abnormality.
--
--
--
--
What kind of heater?
Is the power saving function available on the outdoor unit?
Can the system prepare domestic hot water?
What kind of DHW tank is installed?
What is the pump operation mode?
Brine pressure switch present?
Pump operation allowed outside range.
Above which outdoor temperature is cooling allowed?
--
--
--
--
Close shut-off valve during cooling?
--
Is a bi-zone kit installed?
Power saving function for outdoor unit.
Is an external kWh meter used for power measurement?
--
--
Which type of unit is installed?
Which type of compressor is installed?
What is the indoor unit software type?
Is a DHW tank installed in the system?
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
Is a demand PCB connected?
Is the pump allowed to run if prefer. kWh rate PS is cut?
--
Is an external kWh meter used for power measurement?
What is the unit control method in space operation?
Which type of external sensor is installed?
What is the required alarm output contact type?
--
Which heaters are permitted if prefer. kWh rate PS is cut?
Contact type of preferential kWh rate PS installation?
Bivalent hysteresis temperature.
What is the thermo request contact type for the main zone?
What is the thermo request contact type for the add. zone?
4P569818-1A - 2019.10 (#) Setting is not applicable for this unit. (*1) *X*_(*2) *H*