Setting No. Contents Setting Installer/Serviceman Notes
7 Force Defrost Cycle 0:ON
1:OFF
9 Charge Mode 0:ON
1:OFF
10 Maximum Compressor RPS for Cooling
Depends on tonnage. Can adjust
comp RPS in each 0.5 RPS.
11 Maximum Compressor RPS for Heating
Depends on tonnage. Can adjust
comp RPS in each 0.5 RPS.
12 BOOST MODE Selection
0:ON 1:OFF
13 BOOST MODE Temperature
0:105F, 1:100F, 2:95F,
3:90F, 4:85F, 5:80F, 6:75F,
7:70F, 8:Always ON
15 N/A N/A
16 Noise down level
0:LEVEL1
2:LEVEL3
1:LEVEL2
17 N/A N/A
18 N/A N/A
19 Capacity priority 0:OFF
1:ON
22 DEFROST HEAT
0:Always ON, 1:30F, 2:35F,
3:40F, 4:45F, 5:50F, 6:55F, 7:60F,
8:65F, 9:OFF
*
1
Depending on the connected Indoor unit, there are restrictions on the positive side Trim setting.
If you want to change the Cool Airow Trim to positive side, be sure to conrm the Airow Trim restrictions in the latest Indoor unit
Installation Manual.
The latest Manual can be obtained from the website “DAIKIN CITY (Installation Manual/Unitary Split System)” or “PartnerLink (Info-
FinderPlus/Literature)”.
[DAIKIN CITY URL]
https://www.daikincity.com/Library/
[PartnerLink URL]
https://partnerlinkmarketing.goodmanmfg.com/goodman/info-nder-plus
NOTE: Parameters as per factory setting are highlighted in bold and underlined.
This 7-Segment setting determines Night Mode.
Setting No. Contents Setting Installer/Serviceman Notes
15 Night mode (In case of CTK04)
0:OFF 1:ON
16 Noise down level
0:LEVEL1
2:LEVEL3
1:LEVEL2
17 Night mode start (In case of CTK04)
0:-2Hour, 1:-1Hour, 2:Standard,
3:+1Hour, 4:+2Hour
18 Night mode end (In case of CTK04)
0:-2Hour, 1:-1Hour, 2:Standard,
3:+1Hour, 4:+2Hour
19 Capacity priority 0:OFF
1:ON