CTK04 ADDENDUM
112
H
EAT
P
UMP
A
DVANCED
F
EATURE
M
ENU
COOL SETUP
SUBMENU ITEM USER MODIFIABLE OPTIONS COMMENTS
CL Reset (CL RESET)
*1, *2
(C TR H) -15% to +15% in 5% increments
(C TR I) -15% to +20% in 5% increments, 30%, Full
*3
(C TR L) -15% to +20% in 5% increments, 30%, Full
*3
(CL PRFL)A, B, C, or D Selects the cooling airlow pro ile.
Cool ON Delay (CL ON) 5, 10, 20, 30 seconds Selects the indoor blower ON delay.
Cool OFF Delay (CL OFF) 30, 60, 90, 120 seconds Selects the indoor blower OFF delay.
(DEHUM) STD, OFF, A, B or C
*4
SUBMENU ITEM USER MODIFIABLE OPTIONS COMMENTS
Maximum Compressor RPS Range
for Cooling (COOL RPS RANGE)
will be provided.
Select the appropriate range for the installed system
Maximum Compressor RPS
for Cooling (COOL RPS SELECT)
10 compressor RPS values will be
provided within the range selected in
the COOL RPS RANGE menu
Select the appropriate compressor RPS for the installed
SET COOLING RUN VALUES (CL RUN VALUES)
HEAT SETUP
SUBMENU ITEM USER MODIFIABLE OPTIONS COMMENTS
HT Reset (HT RESET) YES or NO Selecting to default factory setting.
*1
(H TR H) -15% to +15% in 5% increments
-15% to +15% in 5% increments
-15% to +15% in 5% increments
Heat ON Delay (HT ON) 5, 10, 15 seconds Selects the indoor blower ON delay.
Heat OFF Delay (HT OFF) 30, 50, 70, 90 seconds Selects the indoor blower OFF delay.
Maxim um Defrost Interval
(DEFROST)
30 mins., 1 hr., 1.5 hrs. & 2 hrs. Selects time defrost interval
SUBMENU ITEM USER MODIFIABLE OPTIONS COMMENTS
Maximum Compressor RPS Range
for H
(HEAT RPS RANGE)
will be provided.
Select the appropriate range for the installed system
Maximum Compressor RPS
for H RPS SELECT)
10 compressor RPS values will be
provided within the range selected in
the HEAT RPS RANGE menu
Select the appropriate compressor RPS for the installed
SET HEATING RUN VALUES (HT RUN VALUES)
1 DZ20VC0 more
2 connected indoor unit, there Tri
on manual.
3 The Inverte
YES or NO