68
7-SEGMENT DISPLAY-OUTDOOR UNIT
SCREEN 4 (SETTING MODE 2)
Setting
No.
Contents Setting Installer / Serviceman Notes
1 Maximum Defrost Interval
0: 30min.
1: 60min.
2: 90min.
3: 120min.
2 Set Maximum Current N/A Future Use
3 Vertical Rise
0:Same Level
1:Outdoor Lower
2:Indoor Lower
4 System Verification Test (System Test)
0:ON
1:OFF
7 Force Defrost Cycle
0:ON
1:OFF
8 Pump Down
0:ON
1:OFF
9 Charge Mode
0:ON
1:OFF
10 Maximum Compressor RPS for Cooling *
11 Maximum Compressor RPS for Heating *
12
BOOST Mode Selection
0:ON
1:OFF
13
BOOST Mode Temperature
0:105F
, 1:100F, 2:95F, 3:90F,
4:85F, 5:80F, 6:75F, 7:70F,
8:Always ON
*Depends on tonnage. Can adjust compressor RPS in each 0.5 RPS
NOTES:
•
Parameters as per factory setting are highlighted in bold and underlined.
• BOOST MODE is applicable only for DZ20VC0**1AB or later revision.