Main Functions SiBE041102_A
18 Function and Control
1.9 ECONO Operation
The "ECONO operation" reduces the maximum operating current and the power consumption.
This operation is particularly convenient for energy-saving-oriented users. It is also a major
bonus for those whose breaker capacities do not allow the use of multiple electrical devices and
air conditioners.
It is easily activated from the wireless remote controller by pushing the ECONO button.
When this function is activated, the maximum capacity also decreases.
The remote controller can send the ECONO command when the unit is in COOL, HEAT,
DRY, or AUTO operation. This function can only be set when the unit is running. Pressing
the ON/OFF button on the remote controller cancels the function.
This function and POWERFUL operation cannot be used at the same time. The latest
command has the priority.
ECONO Operation
(R9288)
Normal
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
and current

Table of Contents

Other manuals for Daikin FTXN35KEV1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTXN35KEV1B and is the answer not in the manual?

Daikin FTXN35KEV1B Specifications

General IconGeneral
BrandDaikin
ModelFTXN35KEV1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals