SiBE041102_A Main Functions
Function and Control 19
1.10 Inverter POWERFUL Operation
Outline In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Detail When POWERFUL button is pressed, the fan speed and target temperature are converted to
the following states for 20 minutes.
Ex: POWERFUL operation in cooling mode
Operation mode Fan speed Target temperature
COOL H tap + 50 rpm 18°C
DRY Dry rotating speed + 50 rpm Lowered by 2.5°C
HEAT H tap + 50 rpm 31°C
FAN H tap + 50 rpm
AUTO Same as cooling / heating in
POWERFUL operation
The target temperature is
kept unchanged.
(R7096)
Target temp.
Fan
50 rpm
18˚C
H tap
Set tap
20 minutes
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.
It should be the lower limit of
cooling temperature.
It counts 20 minutes. also
in the remote controller.
POWERFUL
ON
POWERFUL
OFF

Table of Contents

Other manuals for Daikin FTXN35KEV1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTXN35KEV1B and is the answer not in the manual?

Daikin FTXN35KEV1B Specifications

General IconGeneral
BrandDaikin
ModelFTXN35KEV1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals