16-80 Fieldbus CTW 1
16-82 Fieldbus REF 1
34-01 PCD 1 Write to
MCO
34-02 PCD 2 Write to
MCO
34-03 PCD 3 Write to
MCO
34-04 PCD 4 Write to
MCO
34-05 PCD 5 Write to
MCO
34-06 PCD 6 Write to
MCO
34-07 PCD 7 Write to
MCO
34-08 PCD 8 Write to
MCO
34-09 PCD 9 Write to
MCO
34-10 PCD 10 Write to
MCO
Select the parameters to be assigned to PCD 3 to 10 of the tele-
grams. The number of available PCDs depends on the telegram
type. The values in PCD 3 to 10 will then be written to the se-
lected parameters as data values. Alternatively, specify a stand-
ard Profibus telegram in par. 9-22.
9-16 PCD Read Configuration
Array [10]
None
16-00 Control Word
16-01 Reference
[Unit]
16-02 Reference %
16-03 Status Word
16-04 Main Actual
Value [Unit]
16-05 Main Actual
Value [%]
16-09 Custom Read-
out
16-10 Power [kW]
16-11 Power [hp]
16-12 Motor Voltage
16-13 Frequency
16-14 Motor Current
16-16 Torque
2. How to Programme FC 300 Programming Guide
136
MG.33.M2.02 - VLT
®
is a registered Danfoss trademark
2