This parameter cannot be adjusted while the motor is running.
[0]
*
No function
[1] Analog input 53
[2] Analog input 54
[7] Frequency input 29
(FC 302 only)
[8] Frequency input 33
[11] Local bus reference
[20] Digital pot.meter
[21] Analog input X30-11
[22] Analog input X30-12
3-19 Jog Speed
Range: Function:
150
RPM
*
[0 - par. 4-13 RPM] Enter a value for the jog speed n
JOG
, which is a fixed output
speed. The frequency converter runs at this speed when the jog
function is activated. The maximum limit is defined in par. 4-13
Motor Speed High Limit (RPM
).
See also par. 3-80.
2.6.4. Ramps
3-4* Ramp 1
For each of four ramps (par. 3-4*, 3-5*, 3-6* and 3-7*) configure the ramp parameters: ramp
type, ramping times (duration of acceleration and deceleration) and level of jerk compensation
for S ramps.
Start by setting the linear ramping times corresponding to the figures.
2. How to Programme FC 300 Programming Guide
76