3.15.6 15-6* Option Ident.
This read-only parameter group contains information about
the hardware and software conguration of the options
installed in slots A, B, C0 and C1.
15-60 Option Mounted
Array [8]
Range: Function:
0* [0 - 30 ] View the installed option type.
15-61 Option SW Version
Array [8]
Range: Function:
0* [0 - 20 ] View the installed option software version.
15-62 Option Ordering No
Array [8]
Range: Function:
0* [0 - 8 ] Shows the ordering number for the installed
options.
15-63 Option Serial No
Array [8]
Range: Function:
0* [0 - 18 ] View the installed option serial number.
15-70 Option in Slot A
Range: Function:
0* [0 - 30 ] View the type code string for the option installed
in slot A, and a translation of the type code string.
For example, for type code string AX, the
translation is No option.
15-71 Slot A Option SW Version
Range: Function:
0* [0 - 20 ] View the software version for the option installed
in slot A.
15-72 Option in Slot B
Range: Function:
0* [0 - 30 ] View the type code string for the option installed
in slot B, and a translation of the type code string.
For example, for type code string BX, the
translation is No option.
15-73 Slot B Option SW Version
Range: Function:
0* [0 - 20 ] View the software version for the option installed
in slot B.
15-74 Option in Slot C0/E0
Range: Function:
0* [0 - 30 ] View the type code string for the option installed
in slot C, and a translation of the type code string.
For example, for type code string CXXXX, the
translation is No option.
15-75 Slot C0/E0 Option SW Version
Range: Function:
0* [0 - 20 ] View the software version for the option installed
in slot C.
15-76 Option in Slot C1/E1
Range: Function:
0* [0 - 30 ] Shows the typecode string for the options (CXXXX
if no option) and the translation is, for example,
No option.
15-77 Slot C1/E1 Option SW Version
Range: Function:
0* [0 - 20 ] Software version for the installed option in option
slot C.
15-80 Fan Running Hours
Range: Function:
0 h* [0 - 2147483647
h]
View how many hours the heat sink
fan has run (increments for each hour).
The value is saved when the frequency
converter is turned o.
15-81 Preset Fan Running Hours
Range: Function:
0 h* [0 - 99999
h]
Enter value to preset the fan running hours
counter, see parameter 15-80 Fan Running
Hours.
This parameter cannot be selected via the
serial port, RS485.
3.15.7 15-9* Parameter Info
15-92 Dened Parameters
Array [1000]
Range: Function:
0* [0 - 9999 ] View a list of all dened parameters in the
frequency converter. The list ends with 0.
15-93 Modied Parameters
Array [1000]
Range: Function:
0* [0 - 9999 ] View a list of the parameters that have been
changed from their default setting. The list ends
with 0. Changes may not be visible until up to
30 s after implementation.
Parameter Descriptions
VLT
®
HVAC Drive FC 102
128 Danfoss A/S © 03/2015 All rights reserved. MG11CE02
33

Table of Contents

Other manuals for Danfoss Metasys N2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss Metasys N2 and is the answer not in the manual?

Danfoss Metasys N2 Specifications

General IconGeneral
BrandDanfoss
ModelMetasys N2
CategoryDC Drives
LanguageEnglish

Related product manuals