FC 300 Design Guide
How to Program
- [0] Off: The store function is inactive.
- [1] Store edit set-up: All parameter values
in the set-up selected in par. 9-70 are
stored in the EEPROM.
The value returns to [0] Off when all
values are stored.
-[2] Store all set-ups: All parameter values for all
set-ups are stored in the EEPROM. The value returns
to [0] Off when all parameter values are stored.
9-70 Edit Set-up
Option:
Factory setup [0]
*
Setup 1 [1]
*
Setup 2 [2]
*
Setup 3 [3]
*
Setup 4 [4]
Active setup [9]
Function:
Edit set-up. Editing can either follow the active
set-up selection (par. 0-10) or be fixed at a set-up
number. This parameter is unique for LCP and buses.
9-72 Drive Reset
Option:
*
No action [0]
Power-on reset [1]
Power-on reset prep [2]
Comm. option reset [3]
Function:
Resets the drive (as for power-cycle). The drive
disappears from the bus, which might cause a
communication error from the master.
9-80 Defined Parameters (1)
Array [1000]
Option:
No LCP access
Read-only
0 - 99 99
*
0
Function:
Holds a list of all the defined drive parameters
available for Profibus.
9-81 Defi ned Parameters (2)
Array [1000]
Option:
No LCP acce ss
Read-only
0 - 9 999
*
0
Function:
Holds a list of all the defined drive parameters
available for Profibus .
9-82 Defi ned Parameters (3)
Array [1000]
Option:
No LCP acce ss
Read-only
0 - 9 999
*
0
Function:
Holds a list of all the defined drive parameters
available for Profibus .
9-83 Defi ned Parameters (4)
Array [1000]
Option:
No LCP acce ss
Read-only
0 - 9 999
*
0
Function:
Holds a list of all the defined drive parameters
available for Profibus .
9-90 Changed Parameters (1)
Array [1000]
Option:
No LCP acce ss
Read-only
0 - 9 999
*
0
Function:
Holds a list of all the drive parameters
deviating from default setting.
*
default setting ()display text []value for use in communication via serial communication port
190
MG.33.B
3.22 - VLT is a registered Danfoss trademark