Product Reference Guide  
          209
Example 1: 
1. $S<CR> 
Enter Service Mode. 
2. $
CLFCA02<CR> 
Write command "Convert to Lower Case" to current configuration. 
3. $Ar<CR
> 
Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode. 
Each configuration parameter setting removes the condition previously active for that 
par
ameter. 
Example 2: 
1. $S<CR> 
Enter Service Mode. 
2. $HA05<CR> 
Select RS232 Interface. 
3. $Ar<CR
> 
Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode. 
Example 3: 
1. $+$!<CR> 
Read Application Software Release. 
Example 4:
Some parameters (ex. Strings) need to insert all the characters (typically 20 Chrs). For example,  
to apply the Chr "T" (0x54) as Serial Stop String:
1. $S<CR>
Enter Service Mode
2. $CSTON5400000000000000000000000000000000000000<CR>
Select the string:"T" (54 = T) as Serial Stop Character
. You must insert all the 20 Chrs (00 
= one empty Chr)
3. $Ar<CR>
Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode.