EasyManua.ls Logo

Datalogic Gryphon I GFS4100 - ACK NAK Timeout Value; ACK NAK Retry Count

Datalogic Gryphon I GFS4100
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS-232/USB-Com Interfaces ENTER/EXIT PROGRAMMING MODE
30
Gryphon™ I GFS4170/GFS4150-9
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host
following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15
seconds) in 200ms increments. A selection of 0 disables the timeout.
See page 237 for more information on setting this feature.
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT
PROG
RAMMING MODE barcode above, then the barcode at
left followed by the digits (in hex) from the Alphanumeric
characters in
Appendix D, Keypad
representing your desired
character(s). End by scanning the ENTE
R/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to abort and not
sav
e the entry string. You can then start again at the begin-
ning.
CANCEL
DEFAULT
01 ACK NAK Timeout value is 200ms
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry
condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and
a selection of 255 specifies unlimited retries. See page 238 for more information.
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT PROGRAM-
MING MODE barcode above, then the barcode at left followed
by
the digits (in hex) from the Alphanumeric characters in
Appendix D, Keypad
representing your desired character(s).
End by scanning the ENTER/EXIT bar
code again.
Make a mistake? Scan the CANCEL barcode to abort and not
sav
e the entry string. You can then start again at the begin-
ning.
CANCEL
DEFAULT
003 = 3 Retries

Table of Contents