Software Configuration Strings
208
Gryphon™ I GFS4170/GFS4150-9
Command Syntax
1. Enter Service (Serial String Programming) Mode
$S<CR>
This command automatically sets the reader communication to
115200 baud rate. Before continuing, please set the baud rate of
the Terminal Emulation Program to 115200.
2. Send Command
Where:
Command: Description
HAXX
Interface Selection
AA
Enable All Symbologies
AD
Disable All Symbologies
R
Reset Reader
CXXXXXX
Write Single Configuration Item to RAM
Parameter:
XXXX
A 4-character ASCII string
See Serial Configuration Strings Table
Value:
XX
A 2-character Hex string
See Serial Configuration Strings Table
3. Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode
$Ar<CR>