ENTER/EXIT PROGRAMMING MODE Character Conversion
Product Reference Guide  
          55
Character Conversion
Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs 
represented in hexadecimal ASCII values. The first character in the pair is the character that will 
be converted. The second character in the pair is the character to convert to. If the character to 
convert in a pair is FF, then no conversion is done.
Configure Character Conversion
To configure this feature, scan the ENTER/EXIT PROGRAMMING 
MODE barcode above, then the barcode at left, followed by the 
digits (in hex) from the Alphanumeric characters in 
Appendix 
D, Keypad
 representing your desired character(s). End by scan-
ning the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to abort and not 
sa
ve the entry string. You can then start again at the beginning.
CANCEL
DEFAULT
0xFFFFFFFFFFFFFFFF
(No character conversion)
If less than the expected string of 16 characters are selected, scan the ENTER/
EXIT barcode twice to accept the selections and exit Programming Mode.