References
250
Gryphon™ I GFS4170/GFS4150-9
7. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming 
Mode.
This completes the procedure.
Wrong Code String
The string sent in case of a mismatch (wrong code read).
To set this feature:
1. Determine the desired character string (max 20).
2. Reference the ASCII Chart on the inside back cover of this manual to find the hex value 
assigned t
o the desired character.
3. Go to Wrong Code String on page 54 and scan ENTER/EXIT PROGRAMMING 
MODE to enter Programming Mode.
4. Scan the barcode: SELECT WRONG CODE STRING.
5. Turn to Appendix D, Keypad and scan the barcodes representing the hex characters deter-
mined in step 1 above.
6. If less than the expected string of 20 characters ar
e selected, scan the ENTER/EXIT bar-
code to terminate the string.
7. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming 
Mo
de.
This completes the procedure.
Label Transmit Mode
Specifies whether the decoded label must be transmitted over the host interface as it has been 
decoded or after the reading phase has been deactivated (phase off). This does not apply to Test 
Mode.