Technical Specifications
Product Reference Guide
259
Standard Cable Pinouts
RS-232 Electrical Connections
9-pin connector
1 Trigger Trigger signal input (see
Figure 36
and
Figure 37
below)
2 TX Transmit Data
3 RX Receive Data
4 NC Not connected
5 GND Ground
6 VCC +5Vdc
7 CTS Clear To Send
8 RTS Request To Send
9 OUT Output signal (see
Figure 35
below)
Default configuration RS-232: 9600, 8, N, 1, no handshaking, ACK/NAK disabled.
Figure 35. Output Connection
OUT
9
30Vdc max
GND
5
Vext
USER INTERFACE
GFS4150-9
Figure 36. Using GFS4150-9 Power
EXT TRIGGER
TRIGGER
1
GFS4150-9
GND
6
5
VCC
Figure 37. Using External Power Supply
EXT TRIGGER
TRIGGER
1
GFS4150-9
30Vdc
max
Vext
GND
5