Software Configuration Strings
230
Gryphon™ I GFS4170/GFS4150-9
Two Reads 
02
Three Reads 
03
Four Reads 
04 
Decoding Level  Disable 
C9DL  00
Level 1 
01
Level 2 
02
Level 3 
03
Level 4 
04
Level 5 
05 
Character Correlation  Disable 
C9CO  00
Enable 
01 
Quiet Zones  No Quiet Zones 
C9LO  00 
Quiet Zone on One Side 
01 
Quiet Zones on Two Sides 
02
 Auto 
03 
Virtual Quiet Zones on Two Sides 
04 
Stitching  Disable 
C9ST  00
Enable 
01 
MSI 
MSI  Disable 
MSEN  00
Enable 
01 
Code Length Control  Variable 
MSLC  00
 Fixed 
01 
Set Length  Length 1 (or Min Length) from 1 to 50 characters 
MSL1  v 
Length 2 (or Max Length) 0 or from 1 to 50 characters 
MSL2  v 
Check Options 
Check Calculation  Disable 
MSCC  00 
Enable Mod 10 
01 
Enable Mod 11/10 
02 
Enable Mod 10/10 
03 
Check Tx  Disable 
MSCT  00
Enable 
01 
Decoding Options 
Minimum Reads  One Read 
MSMR  01
Two Reads 
02
Three Reads 
03
Four Reads 
04 
v
 = Hex value from 
00
 or 
02
 to 
32
 representing the decimal number
CODE SELECTION 
Description Parameter Value