CONTENTS
34
MEMOR™ 30/35 FAMILY
User defined identifier is a user specific character identifier you can set in the related
symbology settings menu.
ECI Policy
Extended Channel Interpretation (ECI) is an extension to the communication protocol
that is used to transmit data from a bar code reader to a host when a bar code symbol is
scanned. It enables the application software to receive additional information about the
intended interpretation of the message contained within the barcode symbol and even
details about the scan itself.
There are two reference models for data interchange in bar coding systems:
The Basic Channel Model (BCM) describes the functional components that co-operate
to convey a message via a traditional bar coding system.
The Extended Channel Model (ECM) adds a processing layer to the front and back ends
of the Basic Channel, to enable ECI-capable data carriers to convey both the message
and information about that message.
Select Transmit to set the data interface in "Extended Channel Mode".
Select Remove to set the data interface in “Basic Channel Mode”.
Check GS1 Format
Enables the check for the GS1 format (applicable to GS1-128, GS1 Databar, GS1 DataMa-
trix, GS1, QR Code, etc.).
Use Human Readable GS1 Format
Enables conversion of GS1 barcodes to the readable GS1 string format when the bar-
code is compliant with GS1 format.
GTIN Format
Sets the representation used for the GTIN-14 format. You can choose between GS1
Databar-14 and GS1-128.
GS1 Label Set Transmit Mode
Sets the mode used to transmit GS1 label sets. A label set consists of all the GS1 bar-
codes that have the same GTIN value. The available options are:
• Disabled: the feature is disabled
• First Label: Send only the first GS1 label found with a given GTIN. The same label
can be sent if the double read timeout has expired without decoding it
• All Labels: Send all the labels found with a given GTIN, adding a prefix to identify
the same label set. The same label set can be sent if the double read timeout has
expired without decoding it
• Prioritize 2D Label: Send 2D label with a given GTIN if decoded, otherwise send
the 1D label if found and if the double read timeout has expired.
GS1 Label Set Prefix
Sets the label set prefix to use when the label set mode is set to All Labels.
GS1 2D Conversion
Sets the conversion used for GS1 2D barcodes. The available options are:
• Disabled: No conversion