REFERENCES
165
5.2.5 Inter-Block Delay
For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20
characters each. The inter-block delay parameter allows setting a delay between
each block sent to the Host.
5.3 NETWORK PARAMETERS
5.3.1 Slave Address Range First/Last
These parameters define the valid addresses for the Slave cradles on the network.
Valid values are in the range 0 to 1999. However, the maximum number of cradles in
a single network is 16, (including the Master if present).
All cradles in the system
must have different addresses
.
To reduce system boot time, it is recommended to number the Slaves consecutively,
while it is not necessary that the Master cradle address is contained in the range.
The network addresses correspond to the radio addresses, see par. 4.7.
At system power-up, the Master searches for and initializes all the Slaves found in
the valid address range. During this phase the yellow LED on the Master cradle
blinks. The time to complete the start up procedure varies depending on the
complexity of the network but is typically between a few seconds to a few minutes.
Start up cannot be interrupted. At the end of this procedure the system will be
operative and can collect data from all devices.
All Slaves must be powered up either before or together with the
Master. Slaves successively powered will not be recognized by
the system even if their address is in the specified range.
CAUTION
5.3.2 Network Warning Message
The Master cradle can transmit warning messages to the Host regarding some
network errors.
/*Slave xxxx not responding*/: when the Master can no longer communicate
with the specified Slave previously identified at start up.
/*Frame out of sequence for terminal xxxx*/: if a reader is sending data
packets out of sequence. This can happen if there are transmission problems
on the network (either connection or communication), or if the reader has
correctly transmitted data to a device not on the network (reader configuration
error).

Table of Contents

Other manuals for Datalogic PowerScan M8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan M8300 and is the answer not in the manual?

Datalogic PowerScan M8300 Specifications

General IconGeneral
Scanner type1D
Maximum range30 m
Read rate (max)40 reads/s
Yaw reading angle-60 - 60 °
Decoding standardsGS1 DataBar, Code 16K, Code 49, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional
Tilt reading angle-20 - 20 °
Pitch reading angle-55 - 55 °
Operating time240 min
Dimensions (WxDxH)114 x 69 x 210 mm
BluetoothNo
Operating frequency910 MHz
Input voltage10 - 30 V
Battery capacity2150 mAh
Power requirements0.33 - 1A
Number of reads per charge60000
CertificationIP64, China RoHS, EU RoHS, CDRH Class II, IEC 60825-1 Class 2
Keys quantity3 keys
Product colorBlack, Yellow
LED indicatorsCharging, Power
Display resolution32 x 96 pixels
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Weight and Dimensions IconWeight and Dimensions
Weight393 g

Related product manuals