When one read per cycle is selected, the device decodes only one code during the
ON period
and immediately turns the reader OFF
. It is only possible to read another
code when the next ON time occurs.
In multiple reads per cycle, the ON period is extended so that the device can
continue decoding codes until an OFF event occurs. For software trigger mode, the
flash on period is immediately reset after each read and therefore extended. If
another code is decoded before the reset flash on period expires, it is again reset
and the effect is that the device remains ON, decoding codes until the flash on or
timeout period expires.
The Safety Time parameter should be used in this case to avoid unwanted multiple
reading of the same code, see par. 5.6.5.
5.6.5 Safety Time
Safety time prevents the device from immediately decoding the same code more
than once. Same code consecutive reading can be disabled requiring the reader to
be removed from the code (no decoding) for at least 400 ms, or a timeout can be set
up to 9.9 seconds before the decoder will accept the same code. Reading is
immediate if the code changes.
The safety time parameter is not applicable when reading stacked codes or when
setting one read per cycle in hardware trigger operating mode, since these settings
require voluntary action by the user.
5.7 DECODING PARAMETERS
These parameters are intended to enhance the decoding capability
of the reader for particular applications. Used incorrectly, they can
degrade the reading performance or increase the possibility of a
decoding error.
CAUTION
5.7.1 Ink-Spread
The ink-spread parameter allows the decoding of codes, which are not perfectly
printed because the page texture tends to absorb the ink.
5.7.2 Overflow Control
The overflow control parameter can be disabled when decoding codes printed on
small surfaces, which do not allow the use of an overflow space.
This command does not affect code families 2/5, Code 128 and Code 93.

Table of Contents

Other manuals for Datalogic PowerScan M8300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan M8300 and is the answer not in the manual?

Datalogic PowerScan M8300 Specifications

General IconGeneral
Scanner type1D
Maximum range30 m
Read rate (max)40 reads/s
Yaw reading angle-60 - 60 °
Decoding standardsGS1 DataBar, Code 16K, Code 49, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked, GS1 DataBar Stacked Omnidirectional
Tilt reading angle-20 - 20 °
Pitch reading angle-55 - 55 °
Operating time240 min
Dimensions (WxDxH)114 x 69 x 210 mm
BluetoothNo
Operating frequency910 MHz
Input voltage10 - 30 V
Battery capacity2150 mAh
Power requirements0.33 - 1A
Number of reads per charge60000
CertificationIP64, China RoHS, EU RoHS, CDRH Class II, IEC 60825-1 Class 2
Keys quantity3 keys
Product colorBlack, Yellow
LED indicatorsCharging, Power
Display resolution32 x 96 pixels
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Weight and Dimensions IconWeight and Dimensions
Weight393 g