Extended System-Level Command Functions
44 Class Series 2 Programmer’s Manual
Configuration Set Commands
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Menu Item (or Number)
(if available)
Command
Equivalent
Alignment Length
AL
0 – 999 1/100 inch (18) N/A
Backup After Print
BA
Y, N
Y = Enabled,
N = Disabled
System Settings N/A
Backup Delay
BD
0 – 255 1/50 second System Settings N/A
Backup Label
BL
0, 3, 4
0 = Disabled,
3 = Active Low,
4 = Active High
Printer Options N/A
Backup (Reverse) Speed
BS or bS
alpha character
Model specific
ranges; see
Appendix L.
Print Control
pa
British Pound
BP
Y, N
Y = Enabled,
N = Disabled
N/A N/A
Buzzer Enable
BZ
Y, N
Y = Enabled,
N = Disabled
System Settings N/A
(continued)