Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 45
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Menu Item (or Number)
(if available)
Command
Equivalent
Column Adjust
[1]
CA
xxx dots
Resolution specific;
see Appendix K,
and Column Adjust
Fine Tune
Print Control (7) N/A
Column Adjust Fine
Tune
CF
+ / – dots
Resolution specific;
see Appendix K.
Print Control N/A
Column Offset
CO
0 – 9999 1/100 in.
Print Control
Cnnnn
Comm Heat Commands
CH
Y, N
1, 0
Y = Enabled,
N = Disabled
1 = Enabled,
0 = Disabled
Communications (25)
(E-Class - 24)
N/A
Comm Speed Commands
CS
Y, N
1, 0
Y = Enabled,
N = Disabled
1 = Enabled,
0 = Disabled
Communications (26)
(E-Class - 24)
N/A