Extended System-Level Command Functions
Class Series 2 Programmer’s Manual 65
(DR) Delay RateThis command sets the number of minutes to delay between
multiple batch printings of Quick Test Labels.
(DS) Double Byte Symbol Set – See <STX>y or ySxx for command details.
(EM) Input Mode – This command determines the data processing mode:
Value Interpretation
Input Mode Interpretation
0 DPL Character strings are parsed for standard DPL processing.
1 Line
No parsing occurs; instead, each carriage return (<CR>)
terminated data line is printed according to a stored template
(see Appendix S).
3 PL-Z
Character strings are parsed for PL-Z processing, applicable
only if the appropriate firmware is installed, as indicated by a
“Z” in the version string (except for H-Class and M-Class
Mark II, which is standard).
For RFID, the hardware option, tag type and size
should be preselected, and a tag calibration performed.
Also, if possible, driver / software options to use
“Printer Defaults” should be chosen to minimize
potential conflicts.
7 PL-B
Character strings are parsed for PL-B processing, applicable
only if the appropriate firmware is installed, as indicated by a
“B” in the version string.
9 Auto
Character strings are automatically parsed and processed
according to the identified language.
A clean file is required, where extra leading characters
may cause the language to be unrecognizable;
otherwise, the appropriate Input Mode must be
selected.
(EN) End Character – This command terminates a <STX>Kc string.