DLS / DLS-C Series
111
Cod.: 240.010.0042
DLS 300 DLS 450 / DLS 450H DLS 600L / DLS 600
Warranties 5 years (as standard)/10 year (optional)
Environmental conditions
Ambient temperature -20°C…+60°C
Power derating temperature range 40°C…+60°C
Storage temperature -30°C…+70°C
Relative humidity 5%...95% without condensation
Noise levels < 50 dB(A) @ 1 m
Maximum operating altitude without derating 2000 m
Pollution degree classifcation PD 3
Installation environmental category Indoor, unconditioned
Physical
Protection rating IP 21
Overvoltage category (IEC 62109-1)
II (DC, BATTERY inputs)
III (AC output)
Cooling concept I-cool, forced cooling
Dimensions (W x H x D) mm 710 x 650 x 150
Weight 30 kg
Fitting system Staffa a parete
Safety
Protection class I
DC to AC isolation Trasformerless
BATTERY to AC and DC isolation with safety HF transformer
Certifcations CE
EMC and Safety standards
EN61000-6-2 (EMC); EN61000-6-3 (EMC);
EN 62109-1 (Safety); EN 62109-2 (Safety)
Grid codes CEI 0-21 (IT); VDE 0126-1-1 (DE); VDE AR-N 4105 (DE); G98/G99 (UK); C10-11 (BE)
Other features
BACKUP/OFF-GRID mode operation Yes, with internal interlock (*)
ON-GRID/BACKUP/OFF-GRID selection mode Yes, automatic
Grid support (grid services) Yes, if required by the applied grid code
Residential loads management Yes, 1 dry contact 4A 250Vac
(*) The specifed range or function may vary according to the grid code and safety rules applied in the country of installation..