One U ReadyRails installation
S5224F-ON, S5248F-ON, and S5232F-ON switches, you can install the ReadyRails system using the 1U tool-less square-hole method or
one of three possible 1U threaded round-hole methods. The tooled installation methods include two-post ush mount, two-post center
mount, or four-post threaded mount.
NOTE
: Do not use the ReadyRails system for the S5212F-ON and S5296F-ON switches. For the S5212F-ON switch installation
instructions, see One-half U front-rack installation. For the S5296F-ON switch installation instructions, see Two U four-post rack
assembly.
To begin installation, separate each rail assembly by sliding the inside rail out of the outside rail.
NOTE
: For more installation instructions, see the installation labels attached to the rail assembly.